CSI Ulraflex

Problem Remedy
Ultraflex water valve will not cycle After confirming all water is properly routed to the valve, check to see that all the power connectors are secure and intact at the source.

1. Make sure GFI is not tripped. Next, check connector of the electrical cable at the control panel and at the water valve.

2. Make sure indicator light for the water valve comes on when rotating.

3. Make sure valve is not in pause mode.

4. Check pressure switch wiring connections.

 
Pressures lower than normal 1. Backwash filters, check screens or pump baskets

2. Make sure all manual auxiliary lines in the system are closed.

3. O-rings leaking are worn at indexing tee - replace.

 
Two ports emitting water at the same time Evidenced by observing increased pressures at the begining of index.

 
Valve will not cycle 1. Check connections at control panel and at valve.

2. Confirm proper schematic connections and secure connections.

 
Valve does not pause on an outlet port 1. Valve cover not in palce

2. Sensor defective or damaged - replace

 
Valve leaking around motor shaft 1. Replace shaft seal

 
Water in valve box 1. Top plate not tight - Retighten or replace body o-ring

2. Shaft seal leaking - Replace

 
Fan does not run 1. Only runs when valve is rotating and valve cover is in place.